EDC 01: Equipment for Damage to Conductors

imgprincipal

EDC 01: Damage to Conductors - BSEN 60669-1 / BS 5733 / IRAM NM 60884-1.

BSEN 60669-1 clause 12.2.5. Screw-type terminals shall be so designed and constructed that they clamp the conductor(s) without undue damage to the conductor(s).

Specifications

Our equipment Damage to Conductor was designed and manufactured to perform the test specified in many standards (IRAM 60884-1, BSEN 60669-1, BS 5733) to the damage to conductors.

You only should set: The time test.

Making the test:

  • add Place the sample in the test sample holder support.
  • add Place the wire in the sample and pass it through the hole in the plate assay.
  • add Place the corresponding weight (or the set of weights to reach the required weight.
  • add Turn on the equipment.
  • add Go to the screen test and press the START key to start the test.
  • add Adjust the speed with the knob.
  • add Press PAGE key if you want to reset the lap counter and time.
  • add The machine automatically stops when it reaches the time set on the equipment test.

EQUIPMENT SPECIFICATIONS

Power Supply
220Vca, 50 Hz, 6 A, Single-phase
Fuse rating: 5 A rapid 20 x 5 mm.
Specifications
done Totally controlled by microcontroller.
done Test 100% automatic.
done Plug & Play: only you must connect it to the power supply, turn on and begin it to realize tests.
done Speed regulation.
done Display LCD.
You can see
done Time of each test.
done Speed revolutions (RPM).
done Laps counter.
Dimensions
450mm x 450mm x 1050mm (h).
Weight approx: 35 Kg.
According to
done IRAM NM 60884-1.
done BSEN 60669-1.
done BS 5733.

©2019 SECOM. Todos los derechos reservados.