ATTENTION: Due to the impact of the COVID-19 Virus, our normal lead times for service and sales may be extended. We thank you for your understanding and will do our best to communicate any delays to you.

ETR 01: Residual Voltage tester

imgprincipal

ETR 01: Residual Voltage tester - IEC 60335-1

Equipment designed and developed for the test in Clause 22.5 of IEC 60335-1 standard.

Equipment designed and developed for the test in Clause 22.5 of IEC 60335-1 standard.

22.5 Appliances intended to be connected to the supply mains by means of a plug shall be constructed so that in normal use there is no risk of electric shock from charged capacitors having a rated capacitance exceeding 0,1 μF, when the pins of the plug are touched.

Compliance is checked by the following test.

The appliance is supplied at rated voltage. Any switch is then placed in the off position and the appliance is disconnected from the supply mains at the instant of voltage peak. One second after disconnection, the voltage between the pins of the plug is measured with an instrument that does not appreciably affect the value to be measured.

The voltage shall not exceed 34 V.

Make a test:

  • First, check the setpoints on the equipment.
  • Connect the equipment to be tested in the socket test.
  • Position yourself on the screen No. 3 (home screen test).
  • Press the Start button, and automatically the equipment start the test.
  • Actuate the contactor that feeds power to the equipment under test.
  • The equipment, start to discount the Time ON.
  • After elapsed time of testing, the equipment under test will shut down, and the equipment start to deduct the waiting time.
  • When it reaches 0, the equipment, measure the residual voltage left in the equipment under test, the display screen and a beep sounds indicating that the test is complete.

TECHNICAL SPECIFICATIONS

Power Supply
220Vca, 50 Hz, 6 A, single phase (115 Vca optional).
Gabinete
Gabinete para mesa.
Indicator
Display LCD 2 lines.
Control
Totally controlled by microprocessor.
Test
Test Voltage: According to input voltage.
MAX Current test: 5 Aca.
To test apparatus Class I.
Dimensiones
260mm x 200mm x 150mm (h).
Weight: 2 Kg.
Guarantee
12 months.
According to
IEC 60335-1 (Clause 22.5).

©2019 SECOM. Todos los derechos reservados.

©2019 SECOM. Todos los derechos reservados.